I think the diagram on the README is flipped from the one you shared. Either I read it wrong too or it's flipped :-)
I'll keep this open while we discuss what to change.
from esphome-econet.
When you say "not getting any data" you mean that in the logs you're not seeing any data coming back on any of the datapoints?
Usually this means your wires are not corrected to the right connectors. Do NOT trust the colors as it seems like they are not consistent between cables. Can you verify that you have RJ11 Pin 3 going to B, Pin 4 going to A, and Ping 5 going GND as shown in the diagram at https://github.com/esphome-econet/esphome-econet#hardware-installation ?
If that isn't clear or doesn't work, you might try sharing some further details over in our Discord.
I have a very similar model (PROPH80 T2 RH375-30) so I'm fairly confident it should work.
from esphome-econet.
Yes, all the water heater data elements show "Unknown", but I can restart the ESP using the "Restart ESP" option in HA.
Here's the the wiring for verification:
Please LMK what other information I can provide. Thanks.
from esphome-econet.
Yeah, your wires on your plug are different colors than what's show in the diagram. It looks like you need to go:
Green -> B
Red -> A
Black -> Ground
from esphome-econet.
Oops, that was a total rookie mistake on my part reading the pin-outs inverted...
Sorry about that and thanks much for the prompt help!
So that others may avoid my moment of stupid, it might be helpful to have a graphical representation of the pin-out posted in the instructions similar to this:
Image Attribution: https://www.geeksforgeeks.org/rj11-color-code/
Thanks again!
from esphome-econet.
Are the colors indicated on the README wrong for what you expect the standard to be based on that article?
Also, can you confirm that your setup is working now?
from esphome-econet.
Sorry, I didn't mean to imply that the instructions as-is are incorrect in any way. Sometimes, it's easy to misread an ASCII diagram as I did when I should have known better, so I'm just suggesting an additional check that may prove helpful/useful to others as well.
Yes, everything appears to be working except for the "Hot Water" value, but I don't think my model supports that anyway.
from esphome-econet.
I was following this as I was waiting for UPS to deliver my hardware; it came, I connected, it worked first try. I do think that the pins in the documentation may be incorrect based on old school telephone cable. I found I had purged all my RJ11/12/etc connectors, but found some flat phone cord. It had the pins reversed from what you showed in terms of colors. I THINK that this may be the difference in RJ9 and RJ11 if this web site is to be believed: https://forum.huawei.com/enterprise/en/differences-between-rj9-rj11-rj12-rj45-and-rj48/thread/673245715150815232-667213852955258880
Here you can see the colors through the back side. To me these are reversed, HOWEVER, most documentation calls for RJ11 to be as you show. So I think (as you already mention) there can be differences in cables and the pinouts are what counts. I followed that (in my case Red-A, Green-B, Black-G) and it is working great.
PS. The working model number is: XE50T10H+45U0 if you are tracking what works and not.
from esphome-econet.
Related Issues (20)
- Nightly Build Failed HOT 1
- Remove improv_serial dependency HOT 1
- Builds still using remote rather than local configs in some places HOT 1
- Add XE50T12CS55U0 to proven model compatibility wiki page HOT 1
- m5 stack boot looping and esphome version missing some details. HOT 28
- Attributes are not getting updated but logs are showing data getting read in HOT 4
- Fully Document Available Datapoints HOT 5
- Water Temperature Set Point Maximum HOT 8
- Rheem Automatic Shut-Off Valve HOT 11
- Constant diconnections HOT 2
- Expose more data for water heaters HOT 16
- Getting error of "[econet:342]: I_RMSVAL : UNSUPPORTED" with latest update HOT 2
- Nightly Build Failed HOT 1
- Add 'hvac_write_float_from_address' HA Service HOT 3
- every datapoint is being requested twice, and REQUEST_ONCE is being ignored HOT 4
- Error when upgrading with esphome 2024.6 - "ESPHome supports certificate verification only via ESP-IDF" HOT 1
- Enable esphome-econet to use new `http-request` OTA capability of ESPHome HOT 2
- No data in the logs HOT 3
- ODI - expose liquid temp HOT 2
- Seems like it's set up, but the only data I'm getting is wifi signal strength. HOT 9
Recommend Projects
-
React
A declarative, efficient, and flexible JavaScript library for building user interfaces.
-
Vue.js
🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.
-
Typescript
TypeScript is a superset of JavaScript that compiles to clean JavaScript output.
-
TensorFlow
An Open Source Machine Learning Framework for Everyone
-
Django
The Web framework for perfectionists with deadlines.
-
Laravel
A PHP framework for web artisans
-
D3
Bring data to life with SVG, Canvas and HTML. 📊📈🎉
-
Recommend Topics
-
javascript
JavaScript (JS) is a lightweight interpreted programming language with first-class functions.
-
web
Some thing interesting about web. New door for the world.
-
server
A server is a program made to process requests and deliver data to clients.
-
Machine learning
Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.
-
Visualization
Some thing interesting about visualization, use data art
-
Game
Some thing interesting about game, make everyone happy.
Recommend Org
-
Facebook
We are working to build community through open source technology. NB: members must have two-factor auth.
-
Microsoft
Open source projects and samples from Microsoft.
-
Google
Google ❤️ Open Source for everyone.
-
Alibaba
Alibaba Open Source for everyone
-
D3
Data-Driven Documents codes.
-
Tencent
China tencent open source team.
from esphome-econet.