Hi Peter,
Thank you for finding the bug ( I have gone a little bit too far with cleaning up).
I repaired and published it (Version 2.0.2)
I do not think that blocking traffic to the growatt server will bring the right results. I think the Growatt shine stick needs communication with the growatt server to be able to send data. If you block that communication no data will be sent at all.
The shine stick will buffer the data untill the session with the growatt server is established. All buffered data will be sent after a reconnect.
If you are succesfull in blocking the communication and still see the data I have to change my ideas about how the communication works. Please let me know.
I am thinking about a third mode (server) in which no connection with Growatt is needed (Grott will act as the Growatt Server) but have to do some more investigation on the protocol used.
See also issue #10.
from grott.
Hi Johan,
Thanks for fixing, the issue!
I will test what wil happen if i block the access to the growatt server, and i will let you know.
Gr,
Peter.
from grott.
Thanks for the great app. I am wondering if the grott server is down, like for a day, and the rerouting of the data doesn't forward to the Growatt servers does than gaps exist in your month and year totals as like it skipped a day?
from grott.
Hi.
Grott doesn't is a server. You are the server so if nothing sent through there is something wrong with your own configuration.
Is your system up? Is grott still runni g? Maybe a restart will help.
from grott.
Sorry for the misunderstanding. I don't have grott running yet. I mend by server, the proxy-server. I now monitor the solar panels by the growatt app for year and month totals.
What I am curious for, if for example, the grott proxy is down for a couple of days for some reasons, is this data lost and unknown by the Growatt app or does the Growatt server and inverter catch up the (offline) days once the grott proxy is up again.
from grott.
In proxy mode data will not be sent to the growatt server anymore.
The inverter (wifi stick) will store the data and it will be sent after the connection is aivalable again. There will be no data lost.
However I do not know for what period data can be stored. In my experience at least more then one day.
In sniffer mode (with ip forwarding) data will be sent to the grottserver if grott is not running and your system is still active.
from grott.
Thanks. I didn't know that the inverter or wifi-stick has a (small) buffer if the connection goes down for a while. Makes sence and is good to know.
I want to still use both apps (the official growatt app and yours) so with the automatic backup-feature in the inverter/stick in mind I can experiment freely with your app and use the sniffer mode.
In sniffer mode (with ip forwarding) data will be sent to the grottserver if grott is not running and your system is still active.
With grottserver you mean growatt server? (typo?)
from grott.
Yes sorry growatt server....
from grott.
In proxy mode data will not be sent to the growatt server anymore.
The inverter (wifi stick) will store the data and it will be sent after the connection is aivalable again. There will be no data lost.
However I do not know for what period data can be stored. In my experience at least more then one day.In sniffer mode (with ip forwarding) data will be sent to the grottserver if grott is not running and your system is still active.
I read somewhere the ShineWifi-X can store 30 days of data
from grott.
Related Issues (20)
- Negative temperatures return 65.535-ish HOT 10
- How to confirm MQTT, Influx and PVOutput is working? HOT 10
- No data PV2, only PV1 - values not correct HOT 6
- Encoding of messages from ShineWifi HOT 1
- Intermittent dropouts in influx recordings HOT 20
- How can I achieve fallback in case of Grott goes down HOT 9
- Grott cannot process the incoming data from the datalogger HOT 1
- HA receiving MQTT data from grott, but not processing it? HOT 1
- Old value messing up data HOT 1
- T06NNNNXTL3 not strict enough HOT 5
- Zero values after Inverter goes offline HOT 8
- PV3 and SPM Meter data are missing on Growatt MIN 10000TL-X configuration HOT 1
- Debug grott container HOT 3
- BMS error 304 HOT 3
- Add license information HOT 2
- Wrong device ID : Xxxxxxxxx HOT 1
- Can I pay one of you to set me up?
- Is there a reason, that 2.7.8 ist still the lasted release? HOT 12
- Password datalogger setting page HOT 1
- Allow domain name in InfluxDB setting
Recommend Projects
-
React
A declarative, efficient, and flexible JavaScript library for building user interfaces.
-
Vue.js
🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.
-
Typescript
TypeScript is a superset of JavaScript that compiles to clean JavaScript output.
-
TensorFlow
An Open Source Machine Learning Framework for Everyone
-
Django
The Web framework for perfectionists with deadlines.
-
Laravel
A PHP framework for web artisans
-
D3
Bring data to life with SVG, Canvas and HTML. 📊📈🎉
-
Recommend Topics
-
javascript
JavaScript (JS) is a lightweight interpreted programming language with first-class functions.
-
web
Some thing interesting about web. New door for the world.
-
server
A server is a program made to process requests and deliver data to clients.
-
Machine learning
Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.
-
Visualization
Some thing interesting about visualization, use data art
-
Game
Some thing interesting about game, make everyone happy.
Recommend Org
-
Facebook
We are working to build community through open source technology. NB: members must have two-factor auth.
-
Microsoft
Open source projects and samples from Microsoft.
-
Google
Google ❤️ Open Source for everyone.
-
Alibaba
Alibaba Open Source for everyone
-
D3
Data-Driven Documents codes.
-
Tencent
China tencent open source team.
from grott.