mvn23 avatar mvn23 commented on August 16, 2024 1

Fixed in 6962e5a

from pyotgw.

mvn23 avatar mvn23 commented on August 16, 2024

Reviewing the changes in HA between 0.99.3 and 0.100.2 I don't see anything that could cause this. pyotgw 0.5b0 will be in the next HA version (probably 0.101) but the only change there is an added disconnect() function.
Does your HA log provide more info?
Please enable debug logging in HA for the following modules:

  • homeassistant.components.opentherm_gw
  • pyotgw.pyotgw
  • pyotgw.protocol

from pyotgw.

andriej avatar andriej commented on August 16, 2024

So far I try to find situation which may cause issues. So far everything seems stable (still), will turn on debug after I find something may cause it.
image

from pyotgw.

andriej avatar andriej commented on August 16, 2024

@mvn23 I've been able to reproduce it 'easily', just changing value via UI.
I've redacted the quite-long log

  1. after startup
  2. normal operation (T/B messages received)
  3. change via UI - where T/B doesn't show anymore
  4. hard reset of power - back to operation

Here is the log - if there's anything to check, let me know.

from pyotgw.

andriej avatar andriej commented on August 16, 2024

During the outage HA showed OTGW as available and even the readings as you can see:
image

from pyotgw.

andriej avatar andriej commented on August 16, 2024

Last time I've been using iSense workaround fix - as it was no-heating time of year, I'm right now not sure if it got migrated into the final code.

I've tried to reproduce issue, so far without success.

from pyotgw.

mvn23 avatar mvn23 commented on August 16, 2024

The iSense fix was integrated in v0.4b3 and I can tell from the logs that it is active in your setup, but thanks for mentioning it as it may be related.
In the log you provided, there seem to be 7 minutes missing around line 145. During that time, the temperature override was activated - seemingly without triggering the issue - while later on changing the override does trigger the issue. How did you activate the override the first time?

from pyotgw.

andriej avatar andriej commented on August 16, 2024

Via HA UI

from pyotgw.

mvn23 avatar mvn23 commented on August 16, 2024

Could you include that part of the log as well?

from pyotgw.

andriej avatar andriej commented on August 16, 2024

I misunderstood, here's the missing part

from pyotgw.

mvn23 avatar mvn23 commented on August 16, 2024

Are you making any calls to the opentherm_gw.set_outside_temperature service? Maybe in an automation? Can you confirm that this is breaking stuff when called manually?

from pyotgw.

andriej avatar andriej commented on August 16, 2024

I'm making indeed - I don't have physical outside temp. sensor connected to boiler so I emulate it with my Aqara zigbee one. Everytime it change it's state, it's reported to boiler (and showed properly on thermostat too).

- alias: "OTGW: set outside"
  initial_state: true
  trigger: 
    platform: state
    entity_id: sensor.temperature_zewnatrz
  action:
    service: opentherm_gw.set_outside_temperature
    data_template:
      temperature: "{{ states('sensor.temperature_zewnatrz') }}"
      gateway_id: "termostat"

I have just tested it by calling it from 'Service' part of HA and - funny part - it showed the -2.5 value (-2.3 reported) on thermostat, but other parts didn't update (like temp change).
In log it seems it got stuck 10 minutes at least before my test, as I was restarting HA.
here's the log

from pyotgw.

mvn23 avatar mvn23 commented on August 16, 2024

Thanks for the log. Also here it seems that the issue is triggered by the outside temperature command.
Can you run some tests with the automation disabled? Just to see if manually running the command causes the issue? I can't reproduce it locally so anything that can narrow down the root cause will help a lot.

from pyotgw.

andriej avatar andriej commented on August 16, 2024

One more test-pattern I've run. Here is the log and here are the steps:
22:28 - HA restart
22:29 - OTGW loads and propagate values
22:30 - 20.5 propagates (set before restart)
22:30 - changed to 21.5 (21 is default on thermostat)
22:31 - changed to 'back to program' on thermostat -> 21 -> HA shows the change
22:33 - on thermostat i set 20
it seems dead now, no further messages (B/T in debug)

I will disable the automation right now and restart (power on/off) the gateway

from pyotgw.

andriej avatar andriej commented on August 16, 2024

So here it is with only one outside report quite long before dead-lock.
Log file
pattern:
22:36 -> 20 -> 21 on thermostat (21 default, "continue program")
22:38 -> 21 -> 22 on thermostat [propagated to HA]
22:39 -> 22 -> 20.5 on HA UI
22:40 -> set outside for -2.3 (default from example)
22:41 -> 20.5 to 21 on thermostat
22:42 -> 21 to 21.5 in HA UI
connection dead (no B/T messages)

from pyotgw.

andriej avatar andriej commented on August 16, 2024

I'd like to come back with any new findings, but since 2019-10-21 02:50:38 (last restart of HA) connectivity is working. I've restarted HA just right now to get logfile lower (it got like >20MB in size).
Also, what I can't see in log are reports of temperature outside, even tho automation is enabled.
It may be because I was changing some things without restarts, will check.

from pyotgw.

andriej avatar andriej commented on August 16, 2024

Just random finding. Next day without 'issue', except - temperature changed first on thermostat, then i UI gives 'O' command all the time in the log. Except, it still works. logfile maybe it will broaden search for issue

from pyotgw.

mvn23 avatar mvn23 commented on August 16, 2024

That would be the iSense fix doing its thing.

from pyotgw.

andriej avatar andriej commented on August 16, 2024

Ok, glad it's working then. :-)
Will look in the log for any issues if they appear.

from pyotgw.

andriej avatar andriej commented on August 16, 2024

Got it! It 'stopped' working exactly the moment that scheduled (on thermostat) value kicked in for night.
log

  • there's gap in time at the end of log after 23:01:18

from pyotgw.

andriej avatar andriej commented on August 16, 2024

I've tried to 'reset gateway' with service from HA. It looks in log like it still can see the values previously, even tho there's no data incoming. Maybe it's worth checking if the B/T messages are there?
Just an idea. log of service reset

what has helped (just wanted to test) was pulling out and putting back in the RJ45 LAN cable.
watchdog triggered and otgw has reconnected logfile from the moment - I guess it confirms it's somehow worth checking the B/T messages

from pyotgw.

mvn23 avatar mvn23 commented on August 16, 2024

The fact that commands are still working and the watchdog is still active leads me to believe that the connection with the gateway remains intact, but the message processing task gets stopped/blocked somehow. Of course I did not build in enough debugging output to confirm this, so we'll have to modify some files first. If I provide you with some .patch files, can you modify your existing pyotgw files or would you prefer I create a custom component?

from pyotgw.

andriej avatar andriej commented on August 16, 2024

I can do both, but patch files seems easier :-) I have it in venv so will be easy.

from pyotgw.

andriej avatar andriej commented on August 16, 2024

One more situation when it was all hanged and re-plug of LAN cable made it reconnect. log

from pyotgw.

andriej avatar andriej commented on August 16, 2024

Just informational: I've moved to 0.101 (if it make any difference for patch files)

from pyotgw.

mvn23 avatar mvn23 commented on August 16, 2024

Sorry for the delay, I will have time to look at this later this weekend.

from pyotgw.

andriej avatar andriej commented on August 16, 2024

Not a problem, I will also be able to start debugging since sunday minimum. :-)
Good thing is, that untouched - it just works.

from pyotgw.

mvn23 avatar mvn23 commented on August 16, 2024

Can you reproduce the issue with the following patch applied to protocol.py and post the debug log?
logging.diff

from pyotgw.

andriej avatar andriej commented on August 16, 2024

First try:
thermostat -> to 22.5
HA -> to 22
thermostat -> to 22.5
thermostat -> to 21
[dead? didn't update in HA]
(tried) HA -> to 23
[temperature changed on thermostat]
[22:29] thermostat -> to 20.5 (again)
[no update in HA]
[22:30] HA -> to 22.5
[updated on thermostat... what is happening?]
[22:31] HA -> to 22 [ok]
[22:33] HA -> to 21
[22:33] thermostat -> to 20.5 [not updated in HA, HA is on 21]
[22:35] thermostat -> to 20 [not updated in HA, HA is on 21]
[22:36] HA -> to 19 [thermostat updated to 19...]
[22:36] HA -> to 18.5 [ok]
[22:37] thermostat to 18 [no updated in HA, stayed on 18.5]
[22:38] on thermostat I cancel override and back to scheduled 21
HA still on 18.5
[22:39] thermostat -> 21.5 [HA still 18.5]
[22:40] HA -> 20
thermostat updated
So far I can't reproduce total connection loss which worries me somehow, as patch is the only LOGGER lines added.
logfile

from pyotgw.

andriej avatar andriej commented on August 16, 2024

[22:56] HA -> 20.5
[22:57] HA -> 20
[22:58] TSTAT -> 19
[22:59] TSTAT -> 20 (not visible in HA, HA still on 19)
[23:00] TSTAT -> cancel override, back to 21 from schedule automatically (HA stay still and show 19)
[23:01] TSTAT -> 21.5 (so back to overriding scheduled value; HA still on 19)
[23:02] HA -> 22 (ok, value changed after a while on thermostat, first 'override' hand icon then the value propagates)
[23:03] TSTAT -> back to 19 (HA still on 22)
[23:04] TSTAT -> cancel override, back to 21 (HA still on 22)

So instead of 'dying' now I have more like a one-way solution.
logfile

from pyotgw.

mvn23 avatar mvn23 commented on August 16, 2024

Looks like my suspicion is being confirmed: The standard T/B/R/A messages stop being processed for some reason and the message queue keeps growing. On both logs you provided, the last message being processed shows a line like this: Processing: A xx 09 xx xx (this is exactly where the iSense quirk is handled)
Can you try a few times and just confirm that the last processed message before the command queue starts growing is one of those? In that case it's definitely a bug in the iSense quirk handling and I will know where to look. This will also explain why I'm not seeing the issue at home.

from pyotgw.

mvn23 avatar mvn23 commented on August 16, 2024

Can you try this possible fix?
maybe_fix.diff

from pyotgw.

andriej avatar andriej commented on August 16, 2024

[16:32] TSTAT -> 28.5
[16:40] HA -> 28
(didn't change on termostat so...)
[16:43] HA -> 27.5

so no effect on iSense while message counter 'works', doesn't go up.
logfile

from pyotgw.

mvn23 avatar mvn23 commented on August 16, 2024

I can tell from the log that your thermostat is not receiving the updated temperatures. The problem is that the thermostat is supposed to request these updates from the OpenTherm Gateway (message T00090000). In the last log you posted (with fix) this does not happen at all.
As the initial problem was likely triggered by the gateway's response to these messages, there's no way to tell if it's fixed from this log.
Do you have an option to reset your thermostat? If it's powered by the gateway this can be achieved by unplugging and re-plugging the gateway.

from pyotgw.

andriej avatar andriej commented on August 16, 2024

Sorry I was resetting my iSense to default and could turn turn off remote control. Ignore last log, will re-check properly all settings before next try!

from pyotgw.

andriej avatar andriej commented on August 16, 2024

[18:31] HA -> 21
[18:31] TSTAT -> 21.5
[18:33] HA -> 22 (for a moment HA showed 20 as setpoint and then proper 22 - I know it's as it should be, just notifying)
[18:34] TSTAT -> 22.5
[18:35] HA -> 23 (again, 20 and updated to 23 seconds after)
[18:35] TSAT -> 23.5
[18:36] HA -> 24 (again, 20 -> 24)
[18:37] TSTAT -> cancel override back to default 20)
[18:37] HA -> 21

ALL of above commands worked properly, problem seems to be fixed!
I'm once again sorry for the reset of iSense and forgot the option of 'remote access' not turned on. I've seen it as F200 error - no external temperature sensor while I was setting whole thing. :-)

Logfile just to confirm it works.

from pyotgw.

Related Issues (20)

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. 📊📈🎉

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google ❤️ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.