This tool is intended to be used as a device testing tool for Azure Stack HCI. For more information on the requirements, please see: Physical network requirements for Azure Stack HCI
- Prepare a host which has at least two NICs which connect to switch device under test (DUT)
- Download
SwitchValidationTool.zip
from Release page and store them in a folder on the host - The tool will scan all active interfaces on the host but only generate report of
LLDP
enabled interface. - Review the sample test data to have better understand the input and output.
- The validation tool will collect network traffic and decode packages to validate protocol value required.
- Upload results under the "Issues" tab in GitHub
flowchart TB
A[Execute Tool] -->|Scan Select Interface| B([Collect and Analyst .pcap file])
C --> |False| E[Review switch configuration]
E --> |Review input variables and test again | A
B --> C{Matches requirements?}
C --> |True| D(Upload result via Issues)
Tested: Windows 11, Windows Server 2019 Untested: Other Windows versions
Tested: Ubuntu Linux 20.04 Untested: Other Linux versions
The following shows the reference lab setup that can be modified accordingly based on needs. The tool can work with virtual interfaces but prefer physical interfaces for testing if possible, which close to the real production senario.
Please check the sample switch configuration for reference.
- LLDP must be enabled.
- A minimum of 10 VLANs must be configured.
Windows folder includes
- SwitchValidationTool.exe
The index of interface which connected to switch is required for Windows OS users, so please check and validate the ifIndex
number for your own test host which will be used for the tool execution.
PS C:\> Get-NetAdapter
Name InterfaceDescription ifIndex Status
---- -------------------- ------- ------
Ethernet 1 Ethernet Adapter 10 Up
Please check Get-NetAdapter for more detail.
Tool must be run with Administrator/Sudo privilege
PS C:\SwitchValidationTool\windows> .\SwitchValidationTool.exe -h
Usage of C:\SwitchValidationTool\windows\SwitchValidationTool.exe:
-InterfaceIndex int
[Windows Only - Get-NetAdapter] index of interface connects with network device to be validated (default 15)
-InterfaceName string
[Linux Only - ifconfig] name of interface connects with network device to be validated (default "eth0")
-allVlanIDs string
vlan list string separate with comma. Minimum 10 vlans required. (default "710,711,712,713,714,715,716,717,718,719,720")
-etsBWbyPG string
bandwidth for PGID in ETS configuration (default "0:48,1:0,2:0,3:50,4:0,5:2,6:0,7:0")
-etsMaxClass int
maximum number of traffic classes in ETS configuration (default 8)
-mtu int
mtu value configured on the switch interface (default 9214)
-nativeVlanID int
native vlan id (default 710)
-pfcMaxClass int
maximum PFC enabled traffic classes in PFC configuration (default 8)
-pfcPriorityEnabled string
PFC for priority in PFC configuration (default "0:0,1:0,2:0,3:1,4:0,5:0,6:0,7:0")
PS C:\SwitchValidationTool\windows> .\SwitchValidationTool.exe -InterfaceIndex 10
2023/05/18 15:31:46 ## Interface Name Ethernet 1 is selected, start collecting packages[Maximum 90s or 300 packages]: ##
2023/05/18 15:31:46
2023/05/18 15:31:47 Collecting Network Packages from Interface Ethernet 1: [1 / 300 (Max)]
2023/05/18 15:31:47 Collecting Network Packages from Interface Ethernet 1: [2 / 300 (Max)]
2023/05/18 15:31:47 Collecting Network Packages from Interface Ethernet 1: [3 / 300 (Max)]
...
2023/05/18 15:31:51 Collecting Network Packages from Interface Ethernet 1: [300 / 300 (Max)]
2023/05/18 15:31:51 ./Ethernet 1.pcap founded.
---------------------
Report Files have been generated.
Linux folder includes
- SwitchValidationTool
Tool must be run with Administrator/Sudo privilege
/SwitchValidationTool/linux $ ./SwitchValidationTool -h
Usage of ./SwitchValidationTool:
-InterfaceIndex int
[Windows Only - Get-NetAdapter] index of interface connects with network device to be validated (default 15)
-InterfaceName string
[Linux Only - ifconfig] name of interface connects with network device to be validated (default "eth0")
-allVlanIDs string
vlan list string separate with comma. Minimum 10 vlans required. (default "710,711,712,713,714,715,716,717,718,719,720")
-etsBWbyPG string
bandwidth for PGID in ETS configuration (default "0:48,1:0,2:0,3:50,4:0,5:2,6:0,7:0")
-etsMaxClass int
maximum number of traffic classes in ETS configuration (default 8)
-mtu int
mtu value configured on the switch interface (default 9214)
-nativeVlanID int
native vlan id (default 710)
-pfcMaxClass int
maximum PFC enabled traffic classes in PFC configuration (default 8)
-pfcPriorityEnabled string
PFC for priority in PFC configuration (default "0:0,1:0,2:0,3:1,4:0,5:0,6:0,7:0")
/SwitchValidationTool/linux $ sudo ./SwitchValidationTool -InterfaceName eth1
2023/05/18 22:42:33 ## Interface Name eth1 is selected, start collecting packages[Maximum 90s or 300 packages]: ##
2023/02/22 19:41:53 Collecting Network Packages from Interface : [1 / 300 (Max)]
2023/02/22 19:41:53 Collecting Network Packages from Interface : [2 / 300 (Max)]
2023/02/22 19:41:53 Collecting Network Packages from Interface : [3 / 300 (Max)]
2023/02/22 19:41:53 Collecting Network Packages from Interface : [4 / 300 (Max)]
...
2023/02/22 19:41:56 Collecting Network Packages from Interface : [300 / 300 (Max)]
2023/02/22 19:41:56 ./eth1.pcap founded.
---------------------
Report Files have been generated.
-
To avoid endless running, the tool has preset maximum timeout condition, and will stop collecting whenever hit first.
- 90 seconds
- 300 network packets
-
Please double check the interface connection and configuration if no network packet being collected.
After the tool execution successfully, there will be four
files:
- PDF File
- YAML File
- Log File
- PACP file
Please group them, navigate to "Issues" and submit "Tool upload result" for the Microsoft team to review.
The tool is written by Go and using gopacket which requires libpcap pre-installed. The tool will automatically install libpcap based on OS, so Internet is required for the host.
For Linux: Run sudo apt install libpcap-dev
For Windows, here are options:
The tool is written by Golang, and using gopacket, but the network adapter/interface id/name is difference between Linux and Windows, so has to modified to fit the gopacket.
# Get interface name in Linux
$ ifconfig
eth0: flags=4163<UP,BROADCAST,RUNNING,MULTICAST> mtu 1500
inet 10.0.0.4 netmask 255.255.255.0 broadcast 10.0.0.255
inet6 fe80::20d:3aff:fe6e:8d11 prefixlen 64 scopeid 0x20<link>
ether 00:0d:3a:6e:8d:11 txqueuelen 1000 (Ethernet)
RX packets 2370443 bytes 3200488398 (3.2 GB)
RX errors 0 dropped 0 overruns 0 frame 0
TX packets 407306 bytes 404678996 (404.6 MB)
TX errors 0 dropped 0 overruns 0 carrier 0 collisions 0
# Sample code to use pcap in Linux
handle, err := pcap.OpenLive("eth0", 1600, true, pcap.BlockForever)
# Get interface name in Windows
> Get-NetAdapter | Select-Object InterfaceAlias,InterfaceIndex,InterfaceGuid
InterfaceAlias InterfaceIndex InterfaceGuid
-------------- -------------- -------------
Ethernet 1 3 {89A8C9DB-D0A4-4E79-8D7D-2FB8A578A221}
# Sample code to use pcap in Windows
# "\Device\NPF_" has to be insert with InterfaceGuid
handle, err := pcap.OpenLive("\Device\NPF_{89A8C9DB-D0A4-4E79-8D7D-2FB8A578A221}", 1600, true, pcap.BlockForever)
The tool will print log with collecting process when it successfully run.
2023/05/18 22:42:33 ## Interface Name eth1 is selected, start collecting packages[Maximum 90s or 300 packages]: ##
2023/02/22 19:41:53 Collecting Network Packages from Interface : [1 / 300 (Max)]
2023/02/22 19:41:53 Collecting Network Packages from Interface : [2 / 300 (Max)]
...
2023/02/22 19:41:56 Collecting Network Packages from Interface : [300 / 300 (Max)]
2023/02/22 19:41:56 ./eth1.pcap founded.
---------------------
Report Files have been generated.
The tool is using open source pcap library, which is same tcpdump or Wireshark using, so please try to use tcpdump
or Wireshark
to validate if the selected interface does have certail network traffic being colected, like LLDP or BGP.
- If no packages detected, it proves the lab setup issue, please double check the lab connections.
- If has packages detected, it could be a potential bug of this validation tool, so please file an issue, so we can track on it.
The tool is using open source pcap library, which is same tcpdump or Wireshark using, and a pcap file will be saved in the tool folder after testing. The pcap file be opened by Wireshark
, and you can filter LLDP to check if being collected or not.
Current version is still beta version, so hasn't signed, so that cause the alert, but it will be passed if running with administrator