20210115 17:15:31 LCD Status: True
20210115 17:15:31 Chassis Intrusion Status: True
20210115 17:15:31 Connection to https://esxi-1
20210115 17:15:31 Found pywbem version 0.11.0
20210115 17:15:31 Check classe OMC_SMASHFirmwareIdentity
20210115 17:15:31 Element Name = System BIOS
20210115 17:15:31 VersionString = P89
20210115 17:15:31 Check classe CIM_Chassis
20210115 17:15:31 Element Name = Chassis
20210115 17:15:31 Manufacturer = HP
20210115 17:15:31 SerialNumber = CZJ705****
20210115 17:15:31 Model = ProLiant DL380 Gen9
20210115 17:15:31 Element Op Status = 0
20210115 17:15:31 Check classe CIM_Card
20210115 17:15:32 Element Name = Motherboard
20210115 17:15:32 Element Op Status = 0
20210115 17:15:32 Check classe CIM_ComputerSystem
20210115 17:15:32 Element Name = ESXI-1.****
20210115 17:15:32 Element Name = Smart Array P440ar RAID Controller : Embedded : HPSA1
20210115 17:15:32 Check classe CIM_NumericSensor
20210115 17:15:32 Check classe CIM_Memory
20210115 17:15:32 Element Name = Proc 1 Level-2 Cache
20210115 17:15:32 Element Op Status = 0
20210115 17:15:32 Element Name = Proc 1 Level-3 Cache
20210115 17:15:32 Element Op Status = 0
20210115 17:15:32 Element Name = Memory
20210115 17:15:32 Check classe CIM_Processor
20210115 17:15:33 Element Name = Proc 1
20210115 17:15:33 Family = 179
20210115 17:15:33 CurrentClockSpeed = 2100MHz
20210115 17:15:33 Element Op Status = 2
20210115 17:15:33 Check classe CIM_RecordLog
20210115 17:15:33 Check classe OMC_DiscreteSensor
20210115 17:15:33 Check classe OMC_Fan
20210115 17:15:33 Check classe OMC_PowerSupply
20210115 17:15:34 Check classe VMware_StorageExtent
20210115 17:15:34 Element Name = Disk 1 on HPSA1 : Port 1I Box 3 Bay 4 : 558GB : Data Disk
20210115 17:15:34 Element Name = Disk 2 on HPSA1 : Port 1I Box 3 Bay 3 : 558GB : Data Disk
20210115 17:15:34 Element Name = Disk 3 on HPSA1 : Port 1I Box 3 Bay 2 : 558GB : Data Disk
20210115 17:15:34 Element Name = Disk 4 on HPSA1 : Port 1I Box 3 Bay 1 : 558GB : Data Disk
20210115 17:15:34 Element Name = Disk 5 on HPSA1 : Port 2I Box 3 Bay 5 : 558GB : Data Disk
20210115 17:15:34 Element Name = Disk 6 on HPSA1 : Port 2I Box 3 Bay 6 : 558GB : Data Disk
20210115 17:15:34 Element Name = Disk 7 on HPSA1 : Port 2I Box 3 Bay 7 : 558GB : Data Disk
20210115 17:15:34 Element Name = Disk 8 on HPSA1 : Port 2I Box 3 Bay 8 : 558GB : Data Disk
20210115 17:15:34 Check classe VMware_Controller
20210115 17:15:34 Element Name = Smart Array P440ar RAID Controller : Embedded : HPSA1
20210115 17:15:34 Check classe VMware_StorageVolume
20210115 17:15:35 Element Name = Logical Volume 1 on HPSA1 : RAID 6 : 1117GB : Disk 1,2,3,4
20210115 17:15:35 Element Name = Logical Volume 2 on HPSA1 : RAID 6 : 1117GB : Disk 5,6,7,8
20210115 17:15:35 Check classe VMware_Battery
20210115 17:15:35 Check classe VMware_SASSATAPort
from check_esxi_hardware.
How exactly did you run check_esxi_hardware? Which parameters?
from check_esxi_hardware.
./check_esxi_hardware.py -H HOST -U USER -P PASS -v
from check_esxi_hardware.
As you are using a HP server, can you try with ./check_esxi_hardware.py -H HOST -U USER -P PASS -V hp -v
?
from check_esxi_hardware.
Thank you. It works:
CRITICAL : Smart Array P440ar RAID Controller : Embedded : HPSA1 CRITICAL : Smart Array P440ar RAID Controller : Embedded : HPSA1 - Server: HP ProLiant DL380 Gen9 s/n: CZJ705**** System BIOS: P89 2017-10-25
from check_esxi_hardware.
Great, thanks for the feedback.
from check_esxi_hardware.
Related Issues (20)
- error inconsistent with command line requirements
- clean up /tmp/<ip>_openssl.conf
- Feature Request - Storage Monitoring HOT 7
- SSL problems with older ESXi HOT 5
- The script doesn't work on Ubuntu 20.04 HOT 2
- Error on importing pywbem.cim_http and pywbem.cim_operations HOT 7
- was working fine with esxi 7.0 but not with 7.0.2 anymore HOT 4
- pywbem 1.0 and later no longer support "no_verification" in WBEMConnection HOT 1
- Connection error after ESXi upgrade HOT 8
- Unconfigured Disk flapping VMware ESXi 7.0.3 HOT 6
- cim_operations error HOT 10
- Run check_esxi_hardware.py with readonly user on esxi HOT 3
- ImportError: No module named pywbem | Ubuntu 20.04.03 HOT 7
- Run check_esxi_hardware.py with readonly user on esxi not working HOT 3
- check_esxi_hardware.py fails after ESXI upgrade HOT 6
- ignore certificate check HOT 3
- TypeError: can only concatenate str (not "NoneType") to str
- Is there any way to check HealthState or Status of NIC(vmnic)? HOT 1
- pkg_resources is deprecated HOT 1
Recommend Projects
-
React
A declarative, efficient, and flexible JavaScript library for building user interfaces.
-
Vue.js
🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.
-
Typescript
TypeScript is a superset of JavaScript that compiles to clean JavaScript output.
-
TensorFlow
An Open Source Machine Learning Framework for Everyone
-
Django
The Web framework for perfectionists with deadlines.
-
Laravel
A PHP framework for web artisans
-
D3
Bring data to life with SVG, Canvas and HTML. 📊📈🎉
-
Recommend Topics
-
javascript
JavaScript (JS) is a lightweight interpreted programming language with first-class functions.
-
web
Some thing interesting about web. New door for the world.
-
server
A server is a program made to process requests and deliver data to clients.
-
Machine learning
Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.
-
Visualization
Some thing interesting about visualization, use data art
-
Game
Some thing interesting about game, make everyone happy.
Recommend Org
-
Facebook
We are working to build community through open source technology. NB: members must have two-factor auth.
-
Microsoft
Open source projects and samples from Microsoft.
-
Google
Google ❤️ Open Source for everyone.
-
Alibaba
Alibaba Open Source for everyone
-
D3
Data-Driven Documents codes.
-
Tencent
China tencent open source team.
from check_esxi_hardware.