Hello,
I looked at the Tread #20/32 but I don't understand what I need to adjust for my solution. I would like to control the Soalx inverter with the power meter. I'm using an SDM72 which is not from Solax but which counts 3 phases. Accordingly, the SDM72 also has consultative registers, as is the case with the SDM230 with the 30013 register. For the SDM72 it would be the register 30053 Total System Power. What does the digestion of the Modbus have to look like? AB from the Sloax parallel with Smartmeter and the esphome? The ESP Home only uses one UART. Does the ESPHOME convert any data between smartmeter ans solax inverter?
Many thanks in advance.
Greetings Dirk
Hello,
I have a Solax inverter Model X1-1.1-S-D(L) version Manager.1.07 Master: 1.08 to which I have connected an RS485-to-TTL module and a Wemos D1 mini pin TX (GPIO1) and RX (GPIO3) . Unfortunately I cannot recover the data from my inverter. See logs:
With my oscilloscope I see signals on the TX / RX pins and I see the TX led of RS485 converter blink periodically.
It looks like my inverter modbus is not active. I tried passwords 2014 and 6868 but I have no option for modbus, only DRM (disable)
Could you help me ?`
The solax_meter_gateway
can be used as SDM230-MID-SOLAX (SDM230 with solax firmware) drop-in replacement. The Solax inverter with export control: meter enabled
setting will request the current power consumption periodically. The solax_meter_gateway
responds to this request with a sensor measurement retrieved from another sensor/device.
How to enable the "export control: meter" mode:
Settings -> Pin: 6868 -> Export control -> Meter enable
Probably more Solax inverters are supported. This feature isn't limited to the Solax X1 series.
[15:42:31][VV][modbus_solax:218]: TX -> AA.55.01.00.00.0A.11.02.00.01.1D (11)
[15:42:31][VV][uart.arduino_esp8266:180]: Flushing...
[15:42:31][VV][modbus_solax:083]: RX <- 00.21.00.02.07.EF.00.00.00.1D.00 (11)
[15:42:31][W][modbus_solax:086]: Invalid header.
[15:42:32][VV][scheduler:185]: Running interval 'update' with interval=1000 last_execution=16039 (now=17046)
[15:42:32][VV][modbus_solax:218]: TX -> AA.55.01.00.00.0A.11.02.00.01.1D (11)
[15:42:32][VV][uart.arduino_esp8266:180]: Flushing...
[15:42:32][VV][modbus_solax:083]: RX <- AA.55.00.0A.01.00.11.82.32.00.21.00.02.07.EC.00.00.00.1D.00.00.00.18.09.55.13.80.02.2B.FF.FF.00.00.5D.AF.00.00.10.50.00.02.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.07.A4 (61)
[15:42:32][W][solax_x1:076]: Invalid response size: 50
[15:42:33][VV][scheduler:185]: Running interval 'update' with interval=1000 last_execution=17039 (now=18044)
[15:42:33][VV][modbus_solax:218]: TX -> AA.55.01.00.00.0A.11.02.00.01.1D (11)
[15:42:33][VV][uart.arduino_esp8266:180]: Flushing...
[15:42:33][VV][modbus_solax:083]: RX <- AA.55.00.0A.01.00.11.82.32.00.21.00.02.07.DB.00.00.00.1D.00.00.00.18.09.56.13.81.02.2C.FF.FF.00.00.5D.AF.00.00.10.50.00.02.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.07.96 (61)
// Hybrid.X1.X3-G3.ModbusTCP.RTU.V3.21-.English.pdf
// May be some modes doesn't apply to the X1 mini
static const char *const MODE_TEXT[16] = {
"Wait", // 0
"Check", // 1
"Normal", // 2
"Fault", // 3
"Permanent Fault", // 4
"Update", // 5
"EPS check", // 6
"EPS", // 7
"Self Test", // 8
"Idle", // 9
};
https://github.com/syssi/esphome-modbus-solax-x1/blob/main/components/solax_x1/solax_x1.cpp#L11
Maybe you have communication protocol Invertor <--> Meter
I am investigating:
Solax X1 mini:
That ask every second like a ping. That works.
send solax: b'\x01\x03\x00\x0e\x00\x01\xe5\xc9'
meter SDM230 not from Solax anw: b'\x01\x03\x02\x00\x00'
send solax: b'\x01\x03\x00\x0b\x00\x01\xf5\xc8'
meter SDM230 not from Solax anw: b'\x01\x03\x02\x00\x00'
But that probably Solax request Data:
send solax: b'\x01\x03\x00\x08\x00\x04\xc5\xcb'
meter SDM230 not from Solax anw: b'\x01\x03\x08\x00\x00\x00\x00\x00\x00\x00\x00'
Meter answer: 00 00 00 00 00 00 00 00
I do STM32 rs485 gateway, but need to know from Original Solax Meter what answer.
Maybe someone has that information? Thanks.
Hi There.
I stumbled upon this project, and I´m curious if there is some "external meter functionality" planned?
As you know Solax inverter support external power meters in order to be able to handle export control.
I have a larger PV set than allowed, thus I want to limit the power which gets exportet to the grid.
On the other hand I do not want to always limit the inverter output power because I want to use full PV power when some consumer in my House demands it.
As I have already a power meter installed (no modbus/not supported by Solax) and it´s values are available in my home network, it´d be great to have the possibility to feed these values to the Solax inverter.
Then I would be able to perfectly limit the exported power to the grid.
Originally posted by Sven177 December 8, 2023
Having an Override Switch for the Meter Gateway, to toggle between either listening to an existing sensor´s value to determine the current power demand, or using a fixed value (like 500W) would be nice.
This would allow to "disable" the export control function on the Meter Gateway side whenever needed, while leaving the actual export control function of the Inverter (and according settings) still active and untouched.
(Hope this is the right way for a Feature Request - first time for me) 😉
Hey guys,
thank for this modules. In my case I try to use it with a Solax X1 mini 1.5 V2.
And I only receive the text which is mentioned in the title.
May anyone has the same issue and can help me to fix it.
regards
frank
Hi Sebastian,
the export control is basically working, and I am using 2x D1 Mini Boards for 2 separate inverters.
But sometimes, I get the meter fault error thrown by the inverter and I haven´t yet figured out why.
I found, that the source sensor for power consumption (Shelly 3EM) sometimes takes 10-15 seconds to update values regarding power consumption. To get around this, I added an heartbeat filter to the code, to send the source value to the power demand sensor every (tried) 3 or 5 seconds, even if the power consumtion sensor hasn´t been updated in between.
name: solax-meter-gateway
device_description: "Control the export of a Solax X1 mini via RS485"
external_components_source: github://syssi/esphome-solax-x1-mini@main
external_components:
- source: ${external_components_source}
refresh: 0s
uart:
- id: uart_0
baud_rate: 9600
tx_pin: GPIO12
rx_pin: GPIO14
solax_meter_modbus:
- id: modbus0
uart_id: uart_0
solax_meter_gateway:
solax_meter_modbus_id: modbus0
address: 0x01
# The state of this sensor (instantaneous power in watt) is used as source
power_id: powermeter0
power_sensor_inactivity_timeout: 25s
update_interval: 1s
sensor:
- platform: homeassistant
id: powermeter0
entity_id: sensor.power_consumption
internal: true
force_update: true
filters:
heartbeat: 5s
- platform: solax_meter_gateway
power_demand:
name: "${name} power demand"
text_sensor:
- platform: solax_meter_gateway
operation_mode:
name: "${name} operation mode"
But despite that change, sporadically the meter fault still shows up.
Any ideas what would cause this? Could it be related to using 2 Boards at 2 Inverters sharing the same code?
Out in the field currently (work related), will be back on Thursday to provide according logs or increase the Log Level
Hallo,
nachdem ich endlich dazu gekommen bin das gateway live in betrieb zu nehmen, habe ich festgestellt, dass der Umrichter immer auf "Meter fault" stehen bleibt.
Wenn ich das Log richtig interpretiere, bekoomt das Gateway die Werte vom Meter und kommuniziert auch mit dem Solax Umrichter. Warum geht der Umrichter nicht in die Produktion.
Solax Umrichter ist unter Erweitert - Einspeisebegrenzung auf Meter gestellt und in der Begrenzung auf 20000 für unbegrenzt, oder 0 auf keine Einspeisung gestellt. Der Umrichter bleibt aber mit fehler ausser Betrieb.
Log
INFO ESPHome 2023.5.5
INFO Reading configuration /opt/iobroker/iobroker-data/esphome.0/solax-meter-gateway-esp32.yaml...
INFO Updating https://github.com/syssi/esphome-modbus-solax-x1.git@main
INFO Starting log output from solax-meter-gateway-esp32.local using esphome API
INFO Successfully connected to solax-meter-gateway-esp32.local
[17:53:58][I][app:102]: ESPHome version 2023.5.5 compiled on Jun 14 2023, 11:06:16
[17:53:58][I][app:104]: Project syssi.esphome-modbus-solax-x1 version 2.1.0
[17:53:58][C][wifi:505]: WiFi:
[17:53:58][C][wifi:363]: Local MAC: C4:4F:33:6A:XX:XX
[17:53:58][C][wifi:364]: SSID: 'xxxx'[redacted]
[17:53:58][C][wifi:365]: IP Address: x.x.x.x
[17:53:58][C][wifi:367]: BSSID: B4:FB:E4:74:xx:xx[redacted]
[17:53:58][C][wifi:368]: Hostname: 'solax-meter-gateway-esp32'
[17:53:58][C][wifi:370]: Signal strength: -71 dB ▂▄▆█
[17:53:58][C][wifi:374]: Channel: 11
[17:53:58][C][wifi:375]: Subnet: 255.255.255.0
[17:53:58][C][wifi:376]: Gateway: x.x.x.x
[17:53:58][C][wifi:377]: DNS1: x.x.x.x
[17:53:58][C][wifi:378]: DNS2: 8.8.8.8
[17:53:58][D][sensor:094]: 'solax-meter-gateway-esp32 instantaneous power consumption': Sending state 499.64001 W with 2 decimals of accuracy
[17:53:58][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:53:58][C][logger:301]: Logger:
[17:53:58][C][logger:302]: Level: DEBUG
[17:53:58][C][logger:303]: Log Baud Rate: 115200
[17:53:58][C][logger:305]: Hardware UART: UART0
[17:53:58][C][logger:309]: Level for 'scheduler': DEBUG
[17:53:58][C][uart.arduino_esp32:124]: UART Bus 1:
[17:53:58][C][uart.arduino_esp32:125]: TX Pin: GPIO17
[17:53:58][C][uart.arduino_esp32:126]: RX Pin: GPIO16
[17:53:58][C][uart.arduino_esp32:128]: RX Buffer Size: 256
[17:53:58][C][uart.arduino_esp32:130]: Baud Rate: 9600 baud
[17:53:58][C][uart.arduino_esp32:131]: Data Bits: 8
[17:53:58][C][uart.arduino_esp32:132]: Parity: NONE
[17:53:58][C][uart.arduino_esp32:133]: Stop bits: 1
[17:53:58][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:53:58][C][solax_meter_modbus:096]: SolaxMeterModbus:
[17:53:58][C][solax_meter_gateway:095]: SolaxMeterGateway:
[17:53:58][C][solax_meter_gateway:096]: Address: 0x01
[17:53:58][C][solax_meter_gateway:097]: Power Demand 'solax-meter-gateway-esp32 power demand'
[17:53:58][C][solax_meter_gateway:097]: Device Class: 'power'
[17:53:58][C][solax_meter_gateway:097]: State Class: ''
[17:53:58][C][solax_meter_gateway:097]: Unit of Measurement: 'W'
[17:53:58][C][solax_meter_gateway:097]: Accuracy Decimals: 0
[17:53:58][C][solax_meter_gateway:098]: Operation name 'solax-meter-gateway-esp32 operation mode'
[17:53:58][C][solax_meter_gateway:098]: Icon: 'mdi:heart-pulse'
[17:53:58][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:53:58][C][solax_meter_gateway.switch:068]: SolaxMeterGateway Switch 'solax-meter-gateway-esp32 emergency power off'
[17:53:58][C][solax_meter_gateway.switch:070]: Icon: 'mdi:power'
[17:53:58][C][solax_meter_gateway.switch:091]: Restore Mode: restore defaults to OFF
[17:53:58][C][solax_meter_gateway.switch:052]: Restore Mode: Restore (Defaults to OFF)
[17:53:58][C][mdns:108]: mDNS:
[17:53:58][C][mdns:109]: Hostname: solax-meter-gateway-esp32
[17:53:58][C][ota:093]: Over-The-Air Updates:
[17:53:58][C][ota:094]: Address: solax-meter-gateway-esp32.local:3232
[17:53:58][C][ota:097]: Using Password.
[17:53:58][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:53:58][C][api:138]: API Server:
[17:53:58][C][api:139]: Address: solax-meter-gateway-esp32.local:6053
[17:53:58][C][api:141]: Using noise encryption: YES
[17:53:58][C][mqtt:065]: MQTT:
[17:53:58][C][mqtt:067]: Server Address: 192.168.168.201:2884 (192.168.168.201)
[17:53:58][C][mqtt:068]: Username: 'sonoff'[redacted]
[17:53:58][C][mqtt:069]: Client ID: 'solax-meter-gateway-esp32-c44f336a5301'[redacted]
[17:53:58][C][mqtt:071]: Discovery prefix: 'homeassistant'
[17:53:58][C][mqtt:072]: Discovery retain: YES
[17:53:58][C][mqtt:074]: Topic Prefix: 'solax-meter-gateway-esp32'
[17:53:58][C][mqtt:076]: Log Topic: 'DEBUG'
[17:53:58][C][mqtt:079]: Availability: 'solax-meter-gateway-esp32/status'
[17:53:58][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:53:58][C][mqtt_subscribe.sensor:031]: MQTT Subscribe 'solax-meter-gateway-esp32 instantaneous power consumption'
[17:53:58][C][mqtt_subscribe.sensor:031]: Device Class: 'power'
[17:53:58][C][mqtt_subscribe.sensor:031]: State Class: ''
[17:53:58][C][mqtt_subscribe.sensor:031]: Unit of Measurement: 'W'
[17:53:58][C][mqtt_subscribe.sensor:031]: Accuracy Decimals: 2
[17:53:58][C][mqtt_subscribe.sensor:032]: Topic: SolaxPowerControl/P_Wirk_L1
[17:53:58][C][mqtt.sensor:027]: MQTT Sensor 'solax-meter-gateway-esp32 power demand':
[17:53:58][C][mqtt.sensor:031]: State Topic: 'solax-meter-gateway-esp32/sensor/solax-meter-gateway-esp32_power_demand/state'
[17:53:58][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:53:58][C][mqtt.text_sensor:023]: MQTT Text Sensor 'solax-meter-gateway-esp32 operation mode':
[17:53:58][C][mqtt.text_sensor:024]: State Topic: 'solax-meter-gateway-esp32/sensor/solax-meter-gateway-esp32_operation_mode/state'
[17:53:59][C][mqtt.switch:041]: MQTT Switch 'solax-meter-gateway-esp32 emergency power off':
[17:53:59][C][mqtt.switch:042]: State Topic: 'solax-meter-gateway-esp32/switch/solax-meter-gateway-esp32_emergency_power_off/state'
[17:53:59][C][mqtt.switch:042]: Command Topic: 'solax-meter-gateway-esp32/switch/solax-meter-gateway-esp32_emergency_power_off/command'
[17:53:59][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:53:59][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:53:59][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:53:59][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:53:59][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:53:59][D][sensor:094]: 'solax-meter-gateway-esp32 instantaneous power consumption': Sending state 492.48999 W with 2 decimals of accuracy
[17:53:59][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:53:59][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:53:59][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:00][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:00][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:00][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:00][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:00][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:00][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:00][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:01][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:01][D][sensor:094]: 'solax-meter-gateway-esp32 instantaneous power consumption': Sending state 502.89001 W with 2 decimals of accuracy
[17:54:01][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:01][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:01][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:01][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:01][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:01][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:02][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:02][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:02][D][sensor:094]: 'solax-meter-gateway-esp32 instantaneous power consumption': Sending state 488.06000 W with 2 decimals of accuracy
[17:54:02][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:02][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:02][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:02][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:02][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:02][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:03][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:03][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:03][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:03][D][sensor:094]: 'solax-meter-gateway-esp32 instantaneous power consumption': Sending state 489.59000 W with 2 decimals of accuracy
[17:54:03][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:03][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:03][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:03][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:04][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:04][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:04][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:04][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:04][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:04][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:04][D][sensor:094]: 'solax-meter-gateway-esp32 instantaneous power consumption': Sending state 487.17999 W with 2 decimals of accuracy
[17:54:04][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:04][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:05][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:05][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:05][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:05][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:05][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:05][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:05][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:06][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:06][D][sensor:094]: 'solax-meter-gateway-esp32 instantaneous power consumption': Sending state 493.38000 W with 2 decimals of accuracy
[17:54:06][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:06][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:06][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:06][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:06][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[17:54:06][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[17:54:06][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
From the readme I understand that the SolaX X1 (not mini) isn't supported, but is there any reason to believe this project won't work with that inverter?
I'm in a simiar position to the one another user was in here: #33
The output is the same, with this block repeated every few seconds:
[16:33:29][D][sensor:094]: 'solax-x1-mini temperature': Sending state nan °C with 0 decimals of accuracy
[16:33:29][D][sensor:094]: 'solax-x1-mini dc1 voltage': Sending state 0.00000 V with 1 decimals of accuracy
[16:33:29][D][sensor:094]: 'solax-x1-mini dc2 voltage': Sending state 0.00000 V with 1 decimals of accuracy
[16:33:29][D][sensor:094]: 'solax-x1-mini dc1 current': Sending state 0.00000 A with 1 decimals of accuracy
[16:33:29][D][sensor:094]: 'solax-x1-mini dc2 current': Sending state 0.00000 A with 1 decimals of accuracy
[16:33:29][D][sensor:094]: 'solax-x1-mini ac current': Sending state 0.00000 A with 1 decimals of accuracy
[16:33:29][D][sensor:094]: 'solax-x1-mini ac voltage': Sending state nan V with 1 decimals of accuracy
[16:33:29][D][sensor:094]: 'solax-x1-mini ac frequency': Sending state nan Hz with 2 decimals of accuracy
[16:33:29][D][sensor:094]: 'solax-x1-mini ac power': Sending state 0.00000 W with 0 decimals of accuracy
[16:33:29][D][solax_x1_mini:298]: The device is or was offline. Broadcasting discovery for address configuration...
I have checked the wiring on my RJ45 cable against the RS485 pinout in the X1 mini installation manual and everything's right. Multimeter says there's continuity on A+, B- and GND.
The light on the HW-219 flashes repeatedly so it does seem to be getting communication from at least one side. I've tried both GPIO1/3, which are my D1 mini 32's TX and RX pins, and GPIO16/17.
I was able to sign in to the advanced device menu through the Solax cloud with password 2014 and set the modbus support to "enable" and modbus address to "1".
I tried powering the HW-219 with 5v instead of 3.3 to see if a little extra power would help, but still got nothing.
Any ideas what to try next?
// register 32: Grid voltage fault in 0.1V
// register 34: Grid frequency fault in 0.01Hz
// register 36: DC injection fault in 1mA
// register 38: Temperature fault in °C
// register 40: Pv1 voltage fault in 0.1V
// register 42: Pv2 voltage fault in 0.1V
// register 44: GFC fault
i have a problem with the Solax x1 mini G3 with following errors
[07:18:49][W][solax_x1:083]: Invalid response size: 56
[07:18:49][W][solax_x1:085]: Your device is probably not supported. Please create an issue here: https://github.com/syssi/esphome-modbus-solax-x1/issues
[07:18:49][W][solax_x1:087]: Please provide the following status response data: 00.17.00.00.03.DE.00.00.00.08.00.00.00.05.09.06.13.85.00.48.FF.FF.00.00.00.28.00.00.00.0C.00.02.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.01.00.8A.00.DE (56)
Anyone know is there any similarity with the Solax protocol over modbus to SunSpec used by other solar inverters including SolarEdge ?
Reason for asking is the possibility to fork this into a ESPhome-modbus-SolarEdge project.
A declarative, efficient, and flexible JavaScript library for building user interfaces.
🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.
TypeScript is a superset of JavaScript that compiles to clean JavaScript output.
An Open Source Machine Learning Framework for Everyone
The Web framework for perfectionists with deadlines.
A PHP framework for web artisans
Bring data to life with SVG, Canvas and HTML. 📊📈🎉
JavaScript (JS) is a lightweight interpreted programming language with first-class functions.
Some thing interesting about web. New door for the world.
A server is a program made to process requests and deliver data to clients.
Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.
Some thing interesting about visualization, use data art
Some thing interesting about game, make everyone happy.
We are working to build community through open source technology. NB: members must have two-factor auth.
Open source projects and samples from Microsoft.
Google ❤️ Open Source for everyone.
Alibaba Open Source for everyone
Data-Driven Documents codes.
China tencent open source team.