We all know what radiation is and its harmful effects on humans. Since this danger is not tangible, in connection with this the idea was born to make an indicator for continuous monitoring of the radiation situation.

The device is not designed to measure the level of radiation in the epicentre of a nuclear explosion, but it allows you to constantly monitor changes in background values. This can be useful in the event of man-made disasters or when you or others bring something with increased background radiation into the house. These can be quite harmless-looking things, nevertheless, they carry a direct threat to life and health.

There are many amateur dosimeter projects, for example, one and two. All of them are built according to almost the same schemes associated with the features of the Geiger counters used. The principle of operation of Geiger counters is based on the effect of impact ionization of a gaseous medium under the action of radioactive particles in the interelectrode space at a high accelerating voltage. Accordingly, the meter requires a high voltage source.

How to compile

Follow this article https://zigdevwiki.github.io/Begin/IAR_install/

ATTENTION! THE DEVICE CONTAINS A HIGH VOLTAGE OF 400 VOLTS

Since Jager has a Zigbee network at home, the device will be an element of this network. The circuit does not contain rare elements and is typical for this type of device.

Diagram

The central elements are the SBM-20 Geiger counter and the E18-MS1PA1-PCB Zigbee module. The scheme includes the ability to use either one or two counters to improve the measurement accuracy.

GAINTA 407 case was selected based on the meter size.

PCB

The board was designed by EasyEDA

Production at JLCPCB

The general assembly has no peculiarities, the smallest SMD elements are 0805. The capacitors in the voltage multiplier are 600 volts and are 1206 in size. There is a trimmer resistor on the board to set the high voltage level.

There is a peculiarity in sealing the meter holders since the width of the case does not allow placing two meters and the micro USB connector at a sufficient distance from each other, the holders must be raised above the board. When soldering, use any 0.8-1.0 mm spacer

Physically, you can install counters 90 or 107 mm long. Such as Soviet SBM-20 and SBM-19 or Chinese J305 and M4011.

To revive the device @anonymass wrote an open-source firmware. The firmware implements support for several counters, displaying the number of registered particles per minute with the conversion of these values ​​to the usual μR / h. An important feature is the ability to set the level at which the alarm is triggered. This condition can be tied to the triggering of a physical siren or light bulb as a means of control and using direct binding on the Zigbee device, which will enable notification even if the Zigbee network is not available.

If the board is correctly assembled, after downloading the firmware, it will be possible to "see" the registered particles immediately
Zigbee Geiger SBM-20

Support

Device support is implemented in zigbee2mqtt and SLS Gateway



Settings

  • alert_threshold - set the level in μR / h, when exceeded, the alarm will be triggered

  • buzzer - built-in buzzer (not yet supported)

  • Led - turn on / off the LED displaying particle registration

  • rph - recorded value in μR / h

  • pm - recorded value of particles per minute

  • sensitivity - counter sensitivity (used if item 3 is selected in sensor_type)

  • sensor_type - select the type of meter:

    • SBM-20 / STS-5 / BOI-33
    • SBM-19 / STS-6
    • everything else
  • sensors_count - number of installed counters

The device is also a router in the Zigbee network, which allows you to increase its coverage.

The final assembly includes installing the board into the case and making an end cap with holes for the LED and micro USB connector. These holes can be made in a standard plug, but Jager drew and printed on a 3D printer

That's all, the device is ready to go.

In the photos you can see that Jager's counters are damaged, it so happened that Jager got just such. The damage is much more serious and this can be seen in the photo below, but while maintaining the tightness, they do not affect the operation of the meters.

How to join

  • Reset to FN rebooting device 5 times with interval less than 10 seconds, LED will start flashing during reset

Files to reproduce

Original post by Jager

geiger's People

Contributors

koptserg avatar nurikk avatar xyzroe avatar

Stargazers

 avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar

Watchers

 avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar

geiger's Issues

Alert всегда в состоянии ON

Для проверки alert_threshold выставил в значение 12, Alert сработал и перешел из состояния OFF в ON, после я alert_threshold поправил на значение 20, но Alert теперь всегда в состоянии ON.
Решил что важен переход через "границу" значения - поставил в 13, уровень поднимался до 15-17, и после вернулся на 11-12 (перенес датчик из ванны в зал 🙂 ) , но Alert по прежнему ON.
Возможно я делаю что то не так, подскажите как правильно работать с alert_threshold и alert

strange values

suddenly values have strange results:

payload_raw: object
radioactive_events_per_minute: 44190
radiation_dose_per_hour: 24988064
linkquality: 86

Trim Pot R8 Value

Hi,

On the schematic and BOM, the trim potentiometer is labelled as 200. Is this 200ohm or 200kilohm?

Many thanks!

Buzzer

Hello! Could you add buzzer support? (Signal - BUZ. Contact 10 (P1.5) Е18МS)

Different Zigbee module

Hi!

Is it possible to use different Zigbee module.
Instead of E18-MS1PA1-PCB to use E18-MS1PA2-PCB.

I know of differences between two of them but looks like every module sold now on Ali is PA2 - even if they list it as PA1.

Thank and really great job with this and all similar projects!!!!!!

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. 📊📈🎉

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google ❤️ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.